ENDOVENOUS RADIOFREQUENCY CLOSURE SYSTEM

Endovenous Radiofrequency Closure System

The UNC Endovenous Radiofrequency Closure System consists of a single-use endovenous RF closure catheter and an RF closure generator. It is intended for minimally invasive treatment of great saphenous varicose veins in the lower limbs (superficial veins only).

RF closure generator and closure catheter

RF CLOSURE GENERATOR

UNC Endovenous RF Closure Generator

UNC endovenous RF closure generator
01

Responsive data feedback

  • Real-time temperature-feedback control
  • Real-time adjustment and display of output power to achieve the set temperature
  • Audible indication of generator operating status
02

Convenient user interaction

  • Large LCD touchscreen for convenient operation
  • Quick, simple review of treatment parameters
  • Colour coding indicates parameter ranges
03

Comfortable user experience

  • Compact, lightweight system for portability
  • Ergonomic handle design for comfortable use
  • Power-cord holder for organized cable storage

RF CLOSURE CATHETER

UNC Single-use Endovenous RF Closure Catheter

Single-use endovenous RF closure catheter

Rapid cooling after use

Atraumatic withdrawal

Heats to target in 5 seconds

Target temperature: 120 °C

Precision graduation marks

Supports effective treatment positioning

20-second heating per segment

Efficient venous closure

Closure-catheter advantages

  1. 6 Fr outer diameter for a smaller puncture site.
  2. Flexible polymer construction supports repeated bending and smooth vascular entry.
  3. A guidewire-compatible option is available when needed, with a soft, smooth distal tip for trackability.
  • Working length: 60 cm or 100 cm
  • Heating element: 3 cm or 7 cm
  • Graduation marks assist measurement and spacing indication
  • Strong catheter visibility under ultrasound monitoring
Closure catheters in different configurations

MODEL SPECIFICATIONS

Model specifications

Catheter modelIntroducer sheath
(minimum ID)
Insertable lengthHeating-element diameterHeating-element lengthMaximum power settingDefault target temperature
FAS-200A1 (guidewire type)6Fr(2.0mm)60cm2.0mm3cm18W120℃
FAS-200A2 (guidewire type)6Fr(2.0mm)100cm2.0mm3cm18W120℃
FAS-200A3 (guidewire type)6Fr(2.0mm)60cm2.0mm7cm40W120℃
FAS-200A4 (guidewire type)6Fr(2.0mm)100cm2.0mm7cm40W120℃
FAS-200A56Fr(2.0mm)60cm2.0mm3cm18W120℃
FAS-200A66Fr(2.0mm)100cm2.0mm3cm18W120℃
FAS-200A76Fr(2.0mm)60cm2.0mm7cm40W120℃
FAS-200A86Fr(2.0mm)100cm2.0mm7cm40W120℃